Measurement Tolerance
Main Menu | Connect | Edit Total Station Profile | Tolerance Settings
Total Station Toolbar | Instrument Settings | Tolerance Settings
Use this to set tolerances that are used when you're using the multi-set collection function in FieldGenius.

Horizontal Angle Tolerance (sec)
Use this to specify the tolerance for your horizontal angles in seconds. When you store your multi-set point, if the Standard Deviation exceeds this value you will be notified when you store the point.
Vertical Angle Tolerance (sec)
Use this to specify the tolerance for your vertical angles in seconds. When you store your multi-set point, if the Standard Deviation exceeds this value you will be notified when you store the point.
Distance Tolerance
Use this to specify the tolerance for your measured distances. When you store your multi-set point, if the Standard Deviation exceeds this value you will be notified when you store the point.
Please refer to the Muti-Set topic for more information on how to record a set.